EPOXY FLOORING SYSTEM FOR OFFICES & ADMINISTRATIVE AREAS
Introduction
Office and administrative spaces require flooring that is visually refined, clean, and comfortable while being durable enough to handle daily activity. The system must deliver a professional appearance, minimal maintenance, and resistance to scuffing and wear from foot traffic and furniture movement.
Recommended Use Cases
- Offices and administrative departments
- Meeting and conference rooms
- Reception and waiting areas
- Control rooms and training spaces
Step-Wise System Description
Step 1: Surface Preparation
- Mechanically grind or clean the substrate to remove contaminants.
- All necessary surface repairs, including crack filling or substrate restoration, must be completed prior to the application of any epoxy flooring materials. Ressichem offers a range of suitable crack fillers and repair compounds, including non-shrink cementitious grouts, specifically designed for surface preparation and repair.
- Ensure the surface is sound, dust-free, and moisture content is below 5%.
Step 2: Application of Ressi SLS Primer – 1 (if Required)
- Latex-based primer applied to promote adhesion before self-levelling screed.
Step 3: Application of Ressi SLS 610 Self-Levelling Screed (if Required)
- Provides smooth, level base; allow 7–14 days moisture release. Make sure that moisture is below 5%
Step 4: Application of Ressi EPO Primer LV
- Low-viscosity primer for excellent substrate sealing and adhesion
Step 5: Application of Ressi EPO Tough Might
- High-build solvent-free epoxy coating at minimum 1000 microns thickness.
- Curing time: 48–72 hours (Usable for Light Traffic). 7 Days for Full cure and complete use.
System Advantages
- Smooth, semi-gloss professional appearance
- Resistant to daily wear, chair movement, and light impacts
- Seamless and low maintenance
- Excellent adhesion and longevity
Maintenance Guidelines
- Clean with neutral detergents.
- Avoid harsh chemicals or abrasives.
- Use protective pads under furniture.
- Recoat periodically as needed.
Note: For detailed information regarding mixing ratios, pot life, recoat intervals, coverage, and application environment, it is strongly recommended to refer to the individual product Technical Datassheets (TDS) for all materials used in this system before application.
System Parameters
| Parameter |
Description |
| System Name |
Office & Administrative Areas Epoxy Flooring |
| Area Type |
Offices, Meeting Rooms, Administrative Areas |
| Traffic Exposure |
Light to Medium Duty |
| Primary Requirements |
Aesthetic, Durable, Low Maintenance |
| Optional Layers |
Ressi SLS Primer – 1, Ressi SLS 610 |
| Primer |
Ressi EPO Primer LV |
| Topcoat |
Ressi EPO Tough Might |
| Total System Thickness |
Minimum 1000 Microns |
| Finish Type |
Smooth, Semi-Gloss |
| Curing Time Before Use |
7 Days Full Cure |
| Key Benefits |
Seamless, Durable, Professional Finish |
A Cementitious Surface: (Concrete slab or screed)
B Cracks and surface damage
C Crack Filler and Repairing Materials
D Ressi SLS Primer - 1 (Optional)
E Ressi SLS 610 (Optional)
F Ressi EPO Primer LV
G Ressi EPO Tough Might
H Ressi EPO Tough Might (Marking)